Main Article Content

Authors

Using 313 sera from normal individuals and patients with a variety of illnesses and conditions as well as untreated syphilis with different clinical stages, specificity and sensitivity of the VDRL, RPR, Ff A-ABS, TPHA, and lgM-TP-ELISA assay for Treponema pallidum, were compared. Results gave incidences of false-positive reactions of 24.5%, 11.9%, 5.3%, 2.4%, and 0.6%, respectively. The whole sensitivities found were 78.3%, VDRL; 84.5%, RPR; 95.3%, Ff A-ABS; 90.5%, TPHA; and 98%, lgM-TP-ELISA. The lgM-TP-ELISA assay seems to be an appropriate method for detecting acute or subacute T. pallidum infections and a valuable tool for judging false positive reactions.

Armando Cortés, Departamento de Patología, Facultad de Salud, Universidad del Valle, Cali, Colombia.

Departamento de Patología, Facultad de Salud, Universidad del Valle, Cali, Colombia. 

Rosalba Rosado, Banco Nacional de Sangre y Laboratorio Clínico,  Cruz Roja Colombiana, Bogotá, Colombia. 

Banco Nacional de Sangre y Laboratorio Clínico,  Cruz Roja Colombiana, Bogotá, Colombia. 

Liliana Castrillón, Banco Nacional de Sangre y Laboratorio Clínico,  Cruz Roja Colombiana, Bogotá, Colombia. 

Banco Nacional de Sangre y Laboratorio Clínico,  Cruz Roja Colombiana, Bogotá, Colombia. 

Bienenstock, J & Bloch. KJ. Sorne characteristic of human conglutinin. J /rnnuuwl, 1966, 96: 637-640. DOI: https://doi.org/10.4049/jimmunol.96.4.637

Franklin, EC. Structure and function of immunoglobulins. N Y J Med, 1968, 69: 411-415.

US Public Health Service. Manual of testfor syphilis. Publication N114 11, Washington, 1969.

Kraus, SJ, Haserick, JR & Lantz, MA. Fluorescent treponemal antibody absorption test reactions in lupus erythematosus: atypical beading pattern and probable false positive reactions. N Engl J Med, 1970, 282: 1287-1290. DOI: https://doi.org/10.1056/NEJM197006042822303

Mackey, DM, Price, EV, Knox, JM & Scotti, AT. Specificity of the FT A-ABS test for syphilis: an evaluation. J Am Med Assoc, 1969, 207: 1683-1685. DOI: https://doi.org/10.1001/jama.207.9.1683

Moore, JE & Mohr, CF. Biologically false positive serologic test for syphilis: type, incidence and cause. J Am Med Assoc, 1952, 150: 467-473. DOI: https://doi.org/10.1001/jama.1952.03680050033010

Wuepper, KD, Bodily, HL & Tuffanelli, DL. Serologic test for syphilis and the false positive reactions. Arch DernUJlol, 1966, 94: 152-155. DOI: https://doi.org/10.1001/archderm.94.2.152

Peter, CP, Thompson.MA & Wilson. DL. False-positive reactions in the rapid plasma reagin-card, fluorescent treponema}. Antibody-absorbed and hemagglutination treponema syphilis serologic test. J ClinMicrobiol, 1979, 9: 369-372. DOI: https://doi.org/10.1128/jcm.9.3.369-372.1979

Brown, ZA & Stenchever, MA. Genital herpes and the FT A-ABS. Obstet Gynecol, 1978, 51: 186-187.

Jaffe, HW, Larsen, S.A. Iones, 00 & Dans, PE. Hemagglutination test for syphilis antibody. Am J Clin PaJhol, 1978, 70: 230-233. DOI: https://doi.org/10.1093/ajcp/70.2.230

Cox, PM, Logan. LC & Stout, GW. Further studies of a quantitative automated micro hemagglutination assay for antibodies to Treponema pallidum. Public Health Lab, 1911, 29: 43-50.

Rudolph, AH. The microagglutination assay for Treponema pallidum antibodies (MHA-TP) is a new treponemal test for syphilis. Where does it fix? J Am Vener Dis Assoc, 1976, 3: 3-8.

Brown. ZA & Stenchever, MA. Genital herpes and the FT A-ABS. Obstet Gynecol, 1978, 51: 186-187.

Cortés, A., Rosado, R., & Castrillón, L. (1993). Comparative sensitivity and specificity of serological tests. Colombia Medica, 24(1), 18–21. https://doi.org/10.25100/cm.v24i1.6458

Downloads

Download data is not yet available.
1 2 3 > >> 

Similar Articles

You may also start an advanced similarity search for this article.